1993 American Eagle 38A. Generator fan.

  • 06/11/2012 9:53 AM
    Message # 961135
    Deleted user
    The onan generator on my coach here in England shut down while I was using it due to overtemperature.I reset the generator from the panel by the TV but there is no fan working now.Apart from the obvious things to check like temp switch and fan motor are there any resettable circuit breakers or remote fan relays that I should be made aware of?.Great coach otherwise,will get to learn all about it eventually. Roger. UK.
  • 08/29/2012 5:18 AM
    Reply # 1059386 on 961135
    Deleted user
    I have traced the fault to a fuse holder which looked serviceable on inspection but proved proved otherwise.Fuse holder changed and problem solved.