HOT WATER BYPASS NO HOT WATER

  • 04/30/2022 3:20 PM
    Message # 12761833
    Anonymous

    Good afternoon, we have a 2017 Fleetwood Bounder 35K. I have located the hot water bypass under the kitchen cabinet. When the lever is in the normal flow, the water does not flow from the hot side. However, when the lever is in the bypass position, the water flows. No hot water just flowing cold. The heater ignites when I turn it on. I am unable to locate any other valve near the hot water heater. I have checked under all cabinets and now looking in all the bays.

  • 04/30/2022 7:05 PM
    Reply # 12761959 on 12761833

    Not sure this will help. We have a 2014 Bounder 35K, our bypass is in the luggage bay just to the right of the water heater vent and drain. 

                            Don

  • 05/01/2022 11:04 AM
    Reply # 12762464 on 12761833
    Anonymous

    Check your wet bay and make sure both of the faucets for your sprayer hose are turned off. on Fleetwood RV's it is a common reason why there is not hot water if they are left on, it allows water to by-pass the water heater.

    Good Luck!

    Dan

  • 05/02/2022 7:21 AM
    Reply # 12763358 on 12761833
    Anonymous

    Good morning

    Thank you for the information.

  • 05/05/2022 6:05 PM
    Reply # 12769202 on 12761833
    Anonymous

    Good afternoon again

    I checked every possible location inside of our RV. I should have looked under it first.

    I have located a hinged door under my water heater and that is the location of the water valve.




    Thanks again for your assistance.